Tomadas
DE USO GERAL (T.U.G.) E ILUMINAÇÃO
1 - TABELAS PARA DIMENSIONAMENTO DE TOMADAS DE USO GERAL (T.U.G.)
Obs.: As tabelas a seguir indicam as quantidades mínimas de tomadas.
1.1 - tomadas para COPAS, COZINHAS e ÁREAS DE SERVIÇO: perímetro tomadas de uso geral (T.U.G.)
(m)
600W
100W
total
2
---2
3,5 < P ≤ 7,0
3
---3
7,0 < P ≤ 10,5
3
1
4
10,5 < P ≤ 14,0
3
2
5
14,0 < P ≤ 17,5
3
3
6
17,5 < P ≤ 21,0
3
4
7
21,0 < P ≤ 24,5
3
5
8
24,5 < P ≤ 28,0
3
6
9
28,0 < P ≤ 31,5
3
7
10
31,5 < P ≤ 35,0
3
8
11
35,0 < P ≤ 38,5
3
9
12
38,5 < P ≤ 42,5
1.2 - tomadas para BANHEIROS: área ( m2 ) qualquer perímetro
(m)
qualquer
T.U.G.
( 600W )
1
1.3 - tomadas para SUBSOLOS, VARANDAS, GARAGENS e SOTÃOS: área perímetro
T.U.G.
( m2 )
(m)
( 100W ) qualquer qualquer
1
1.4 - tomadas para DEMAIS CÔMODOS e DEPENDÊNCIAS: área perímetro
T.U.G.
( m2 )
(m)
( 100W ) qualquer 1
A≤6
2
5,0 < P ≤ 10,0
3
10,0 < P ≤ 15,0
4
15,0 < P ≤ 20,0
5
A>6
20,0 < P ≤ 25,0
6
25,0 < P ≤ 30,0
7
30,0 < P ≤ 35,0
8
35,0 < P ≤ 40,0
1
2 - TABELA PARA DIMENSIONAMENTO DE PONTOS DE LUZ:
área ( m2 )
incandescente(1)
carga ( W ) fluorescente (2)
100
40
A < 10,0
160
60
10,0 ≤ A < 14,0
220
80
14,0 ≤ A < 18,0
280
100
18,0 ≤ A < 22,0
340
120
22,0 ≤ A < 26,0
400
140
26,0 ≤ A < 30,0
460
160
30,0 ≤ A < 34,0
520
180
34,0 ≤ A < 38,0
(1) - iluminação utilizando lâmpadas incandescentes
(2) - iluminação utilizando lâmpadas fluorescentes
(3) - consumo do conjunto lâmpada fluorescente e reator
fluorescente (3)
+ reator
50
75
100
125
150
175
200
225
3 - TABELA AUXILIAR PARA DIMENSIONAMENTO: cômodo ou perímetro tomadas ( T.U.G. ) dependência (m) calculado instalado
área
( m2 )
lâmpadas incandesc. fluoresc.
Obs.: * T.U.G. - quantidade de tomadas de uso geral obtida através das tabelas do item 4.1;
* T.U.E. - quantidade de tomadas de uso