Sistema conectado em rede
02/12/12 Page 1/3
Grid-Connected System: Simulation parameters
Project :
Geographical Site Situation Time defined as
Grid-Connected Project at Faro
Faro Latitude Legal Time Albedo 37.0°N Time zone UT+1 0.20 Country Longitude Altitude Portugal 7.6°W 8m
Meteo data : Simulation variant :
Faro, Synthetic Hourly data New simulation variant
Simulation date
Simulation parameters Collector Plane Orientation Horizon Near Shadings PV Array Characteristics PV module Number of PV modules Total number of PV modules Array global power Array operating characteristics (50°C) Total area Inverter Characteristics
Tilt
lua va E
Si-poly
Free Horizon
No Shadings
de Mo ion t
02/12/12 17h56 30° CPS20 P18 CP-Solar 27 modules 189 3780 Wp 403 V 36.1 m²
Azimuth
0°
Model Manufacturer In series Nb. modules Nominal (STC) U mpp Module area
In parallel Unit Nom. Power At operating cond. I mpp
7 strings 20 Wp 3322 Wp (50°C) 8.2 A
Model Manufacturer Operating Voltage
Sunny Boy SB 3600 TL-21 SMA 175-500 V Unit Nom. Power
3.68 kW AC
PV Array loss factors Thermal Loss factor Uc (const) 20.0 W/m²K => Nominal Oper. Coll. Temp. (G=800 W/m², Tamb=20°C, Wind=1 m/s.) Wiring Ohmic Loss Global array res. Module Quality Loss Module Mismatch Losses Incidence effect, ASHRAE parametrization IAM = 845 mOhm
Uv (wind) NOCT Loss Fraction Loss Fraction Loss Fraction bo Parameter
0.0 W/m²K / m/s 56 °C 1.5 % at STC 2.5 % 2.0 % at MPP 0.05
1 - bo (1/cos i - 1)
User's needs :
Unlimited load (grid)
PVSYST V5.62
02/12/12 Page 2/3
Grid-Connected System: Main results
Project : Simulation variant :
Main system parameters PV Field Orientation PV modules PV Array Inverter User's needs Main simulation results System Production
Grid-Connected Project at Faro New simulation variant
System type tilt Model Nb. of modules Model Unlimited load (grid) Produced Energy Performance Ratio PR Grid-Connected 30° azimuth CPS20 P18 Pnom